Product features:
- Sanitary type to prevent scaling from blocking pressure inlet
- Use of 316L isolation diaphragm and stainless steel case
- Two-wire system standard 4-20mA signal output; customized RS485 signal or HART signal output is available;
- General precision: 0.25 grade, customized 0.1 grade is available;
- Multiple process interfaces and electrical interfaces are available for selection;
- Multiple pressure types are available for selection;
Field of application:
It is mainly used for food, health, wine and other industries that require high sanitary conditions, but also can be used to measure viscous medium to solve the problem that pressure inlet is easy to be blocked.
Technical parameters:
Range
-100~0~5, 100, 500, 800, 1000kPa;0~2, 10……10MPa
Pressure type
Gauge pressure, negative pressure and absolute pressure
Output signal
4~20mA, 4~20mA+HART protocol, 4~20mA+RS485 protocol
Input voltage
12~36V DC
Accuracy
0.1
0.2(0.25)
0.5
Nonlinear repeatability delaying
0.1
0.2(0.25)
0.5
Zero and sensitivity drift
0.01
0.02(0.025)
0.005
Temperature compensation
10℃~70℃
Work temperature
20~+85℃
Long-term stability
≤0.1±%FS/year
Response time
<1ms
Overload capacity
200%
Load resistance
R=(U-12.5)/0.02-RD
U=power voltage; RD=internal resistance of power source
Measurement medium
Corrosive media compatible with 316L
Diaphragm material
316L stainless steel
Case material
1Cr18Ni9Ti
Protection rating
IP67
LONN-3PX Clamp Flat-diaphragm Pressure Transducer
Download: here